FOR USE IN THE U.S. AND CANADASAFETY NOTICE: IF THIS HARMAN TLC 2000 STOVE IS NOT PROPERLY INSTALLED, AHOUSEFIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW
TLC 2000 Coal Stove10Disposal of Ashes. The TLC 2000 was designed toprovide access to the ash pan without the need for openingthe main door. Wearing h
TLC 2000 Coal Stove11Like all fine equipment, your TLC 2000 re-quires some routine maintenance and inspection.Follow the guidelines in
TLC 2000 Coal Stove12GasketsGaskets are used on the doors and top lid of the TLC2000. You must check these gaskets from time to time, andreplace them
TLC 2000 Coal Stove13InstallationDO NOT INSTALL IN A SLEEPING ROOMAssemblyBlower ( Optional )Bolt the blower to the bottom rear of the stove withfou
TLC 2000 Coal Stove14Parallel versus Corner Installations A parallel installation is one in which the backand sides of the stove are parallel to the w
TLC 2000 Coal Stove15The Chimney SystemCreosoteWhen wood is burned slowly, it produces tar andother organic vapors, as well as soot, which combine wi
TLC 2000 Coal Stove16The NFPA (National Fire Protection Association)permits four methods for passing through a combustible wall.A commonly used met
TLC 2000 Coal Stove17Venting to a Masonry Fireplace ChimneyIn some situations, a code compliant chimneyoriginally used for a masonry firepl
TLC 2000 Coal Stove18Caution: Always wear fire-resistant gloves tooperate the stove. The air control is hot whilein operation.Installing to a Prefab
TLC 2000 Coal Stove19TLC 2000 Parts List1. 1-10-08074 TLC Rear Top2. 2-00-852129 TLC Rear Hinge (2 per unit)3. 1-10-08127 TLC Front Top Assembly4. 1-0
TLC 2000 Coal Stove2 U.S.A.INDEXSpecifications 4Operation 6Building a Fire 7Maintenance
TLC 2000 Coal Stove202628122212991418121310B27322456323178A11A231716A2015192524308B3310A11B16B34. Brick Backers (2)35. 1/4 & 1/8 Dowel Pins (2)
21Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use andservice, for a period of 6 ye
TLC 2000 Coal Stove3 WARNINGS(Never sleep in the same room with any coal burning stove.)Carbon Monoxide (CO) AwarenessCarbon monoxide referred to as C
TLC 2000 Coal Stove4Specifications - Harman TLC 2000Weight 375 lbsFlue Size 6 inchLog Length Recommended 16" with 18" MaxHeating Capacity 1,
TLC 2000 Coal Stove5Top Load DoorTop LoadDoor ArmSide ShieldAsh Door LatchAsh DoorCoal Air ControlFront LoadDoor LatchTop Load OpeningGlass DoorGrate
TLC 2000 Coal Stove6OperationThe StoveDoorsYour stove has a large glass-paneled door for loadingand fire viewing, a separate smaller door for
TLC 2000 Coal Stove7Air ControlsCoalThe primary air control for coal burning is a knoblocated on the bottom door. Sliding the knob to the left pro-vid
TLC 2000 Coal Stove8load of dry wood. After adding the fuel, leave air setting atmaximum for 5 to 15 minutes. Then adjust the air controlsand blower
TLC 2000 Coal Stove9Building andMaintaining a Coal FireBuild a wood fire as described but instead of addinglarger wood, limit the size to about 2"